There’s a new trend in high-rise building design. Maybe you’ve seen this in your city. The best lots are all taken, so developers are stretching the limits to make use of space that isn’t always ideal for skyscrapers. They’re not necessarily taller than buildings of the past, but they are a lot more slender. “Pencil tower” is the term generally used to describe buildings that have a slenderness ratio of more than around 10 to 1, height to width. A lot of popular discussion around skyscrapers is about how tall we can build them. Eventually, you can get so tall that there are no materials strong enough to support the weight. But, pencil towers are the perfect case study in why strength isn’t the only design criterion used in structural engineering.
Of course, we don’t want our buildings to fall down, but there’s other stuff we don’t want them to do, too, including flex and sway in the wind. In engineering, this concept is called the serviceability limit state, and it’s an entirely separate consideration from strength. Even if moderate loads don’t cause a structure to fail, the movement they cause can lead to windows breaking, tiles cracking, accelerated fatigue of the structure, and, of course, people on the top floors losing their lunch from disorientation and discomfort. So, limiting wind-induced motions is a major part of high-rise design and, in fact, can be such a driving factor in the engineering of the building that strength is a secondary consideration.
Making a building stiffer is the obvious solution. But adding stiffness requires larger columns and beams, and those subtract valuable space within the building itself. Another option is to augment a building’s aerodynamic performance, reducing the loads that winds impose. But that too can compromise the expensive floorspace within. So many engineers are relying on another creative way to limit the vibrations of tall buildings. And of course, I built a model in the garage to show you how this works. I’m Grady, and this is Practical Engineering.
One of the very first topics I ever covered on this channel was tuned mass dampers. These are mechanisms that use a large, solid mass to counteract motion in all kinds of structures, dissipating the energy through friction or hydraulics, like the shock absorbers in vehicles. Probably the most famous of these is in the Taipei 101 building. At the top of the tower is a massive steel pendulum, and instead of hiding it away in a mechanical floor, they opened it to visitors, even giving the damper its own mascot. But, mass dampers have a major limitation because of those mechanical parts. The complex springs, dampers, and bearings need regular maintenance, and they are custom-built. That gets pretty expensive. So, what if we could simplify the device?
This is my garage-built high-rise. It’s not going to hold many conference room meetings, but it does do a good job swaying from side to side, just like an actual skyscraper. And I built a little tank to go on top here. The technical name for this tank is a tuned liquid column damper, and I can show you how it works. Let’s try it with no water first. Using my digitally calibrated finger, I push the tower over by a prescribed distance, and you can see this would not be a very fun ride. There is some natural damping, but the oscillation goes on for quite a while before the motion stops. Now, let’s put some water in the tank. With the power of movie magic, I can put these side by side so you can really get a sense of the difference.
By the way, nearly all of the parts for this demonstration were provided by my friends at Send-Cut-Send. I don’t have a milling machine or laser cutter, so this is a really nice option for getting customized parts made from basically any material - aluminum, steel, acrylic - that are ready to assemble.
Instead of complex mechanical devices, liquid column dampers dissipate energy through the movement of water. The liquid in the tank is both the mass and the damper. This works like a pendulum where the fluid oscillates between two columns. Normally, there’s an orifice between the two columns that creates the damping through friction loss as water flows from one side to the other. To make this demo a little simpler, I just put lids on the columns with small holes. I actually bought a fancy air valve to make this adjustable, but it didn’t allow quite enough airflow. So instead, I simplified with a piece of tape. Very technical. Energy transferred to the water through the building is dissipated by the friction of the air as it moves in and out of the columns. And you can even hear this as it happens.
Any supplemental damping system starts with a design criterion. This varies around the world, but in the US, this is probability-based. We generally require that peak accelerations with a 1-in-10 chance of being exceeded in a given year be limited to 15-18 milli-gs in residential buildings and 20-25 milli-gs in offices. For reference, the lateral acceleration for highway curve design is usually capped at 100 milli-gs, so the design criteria for buildings is between a fourth and a sixth of that. I think that makes intuitive sense. You don’t want to feel like you’re navigating a highway curve while you sit at your desk at work.
It’s helpful to think of these systems in a simplified way. This is the most basic representation: a spring, a damper, and mass on a cart. We know the mass of the building. We can estimate its stiffness. And the building itself has some intrinsic damping, but usually not much. If we add the damping system onto the cart, it’s basically just the same thing at a smaller scale, and the design process is really just choosing the mass and damping systems for the remaining pieces of this puzzle to achieve the design goal. The mass of liquid dampers is usually somewhere between half a percent to two percent of the building’s total weight. The damping is related to the water’s ability to dissipate energy. And the spring needs to be tuned to the building.
... continue reading